With any construction project there are many factors in the proposed design that will determine the approach to regulatory compliance. The following represents a typical route to UK Building Control compliance for ZONE™ Glazed Structures in the education sector.

Part F – Ventilation of new buildings other than dwellings
Using DTM thermal modelling we demonstrate compliance with the recommended parameters for airflow, solar gain and daytime temperatures generated by the model. Ventilation provision in schools is made in accordance with the guidance in Building Bulletin 101 (Ventilation of School Buildings, Building Bulletin 101, School Building and Design Unit, Department for Education and Skills 2006), CIBSE Guide A and CIBSE TM52. Part L – L2B Conservation of fuel and power in existing buildings other than dwellings ZONE™ Glazed Structures can generally be classified as a building with low energy demand exempt from energy calculations, provided that the thermal capabilities of any adjoining buildings are not compromised. The fixed building services installation is not used to heat the entire enclosed volume of space, only for fixed periods during the day when the building is in use. In order to demonstrate that the year round temperatures will be suitable for the use class we use DTM thermal modelling against BB101, CIBSE Guide A and CIBSE TM52.

Part A – Structural
1.2 Basis of Structural design and loading BS EN 1991-1-3:2003+A1:2015 1.3 Structural concrete BS EN 1992- 1-1:2004+A1:2014 1.4 Structural work of steel BS EN 1993-1-1:2005+A1:2014. Technical requirements for execution of steel structures BS EN 1090-2:2008+A1:2011 Exc. Class 2.

Part K – Protection from Falling, Collision and Impact
Requirement K4 Protection against impact with glazing
Requirement K5 .1 Protection form collision with opened windows
Requirement K5.2 Manifests in glazing requirement
Requirement K5.3 Window controls
Requirement K6 Protection against impact from and trapping by doors

Part M – Building Access – Access to Buildings other than dwellings
M1 Ramped access M1 Handrails to external stepped and ramped access
M1 Accessible entrances M1 Doors to accessible entrances

Part B – Fire Safety
B1 Section 1 Fire alarm and fire detection systems.
Fire Detection & Alarm System – BS5839 part 1, Fire Safety Signage – BS5499 part 1, Emergency lighting –
BS5266 part 1
B1 Section 3 Design for horizontal escape in buildings other than flats
B4 Section 4 Roof coverings
B5 Section 16 Vehicle access

Electrical Installations
Electrical installations are designed, installed and certificated in accordance with BS7671:2008 amendment
3 2015.

Part C – Site Preparation Resistance to Moisture
Section 4 4.6 Ground supported floors (moisture from the ground)

Part H – Drainage
Section 1 Gutters & rainwater pipes. Section 3 Surface water drainage. Section H4 Building over sewers.